pub struct FramedRecvStream {
inner: RecvStream,
buf: BytesMut,
draft: DraftVersion,
subgroup_io: Option<SubgroupObjectReader>,
fetch_io: Option<FetchObjectReader>,
tracking: Option<(TrackObjects, u64)>,
}Expand description
A framed reader for a recv stream. Handles MoQT varint-length decoding.
Fields§
§inner: RecvStream§buf: BytesMut§draft: DraftVersion§subgroup_io: Option<SubgroupObjectReader>Stateful subgroup object reader.
fetch_io: Option<FetchObjectReader>Stateful fetch object reader, holding the prior Object’s Location and the
Group Order its deltas count in. Started by
FramedRecvStream::begin_fetch_objects rather than by the fetch
header, which does not carry the order.
tracking: Option<(TrackObjects, u64)>The record this stream’s objects are measured against, and the Group ID its header named.
One group for the whole stream: a subgroup header names it once and no
object header repeats it. None on a stream that was never given one -
a stream for an alias no live binding names, and every stream built
outside Connection::accept_subgroup_stream.
Implementations§
Source§impl FramedRecvStream
impl FramedRecvStream
Sourcepub fn new(inner: RecvStream, draft: DraftVersion) -> Self
pub fn new(inner: RecvStream, draft: DraftVersion) -> Self
Create a new framed receive stream for the given draft version.
Sourcefn measure_objects_against(&mut self, objects: TrackObjects, group: u64)
fn measure_objects_against(&mut self, objects: TrackObjects, group: u64)
Measure this stream’s objects against objects, all of them in group.
Sourcefn note_subgroup_object(
&self,
object: u64,
status: Option<u64>,
) -> Result<(), ConnectionError>
fn note_subgroup_object( &self, object: u64, status: Option<u64>, ) -> Result<(), ConnectionError>
Judge one object this stream carried against where its track ended.
Sourceasync fn fill(&mut self) -> Result<bool, ConnectionError>
async fn fill(&mut self) -> Result<bool, ConnectionError>
Read more data from the stream into the internal buffer.
Sourceasync fn ensure(&mut self, n: usize) -> Result<(), ConnectionError>
async fn ensure(&mut self, n: usize) -> Result<(), ConnectionError>
Ensure at least n bytes are available in the buffer.
Sourcepub async fn peek_stream_type(&mut self) -> Result<u64, ConnectionError>
pub async fn peek_stream_type(&mut self) -> Result<u64, ConnectionError>
Read this stream’s leading variable-length integer without consuming it, and return its value.
Every unidirectional MoQT stream on draft-18 opens with a varint
naming what it is (Section 3.4): 0x05 for FETCH_HEADER, 0x10-0x1D for
SUBGROUP_HEADER, and CONTROL_STREAM_TYPE for SETUP. Telling the
peer’s control stream apart from a data stream means reading that
varint, and taking it off the transport would destroy it: the control
stream’s type varint is the SETUP message’s type field, so a stream
whose type had been stripped would no longer decode as a SETUP.
Nothing is stripped. The bytes land in this reader’s own buffer, and
every other method here — read_control,
read_subgroup_header,
read_fetch_header — decodes out of that
buffer and advances it only on a successful decode. A stream this was
called on is indistinguishable from one it was not, which is what
makes it safe to peek a stream and then hand it to whichever reader
the type turned out to call for.
It reads, so it can block: a peer that opens a stream and then writes nothing leaves this pending until a byte arrives or the stream ends.
§Errors
ConnectionError::UnexpectedEndif the stream ends before a whole varint has arrived.ConnectionError::Transportif the peer reset the stream.ConnectionError::VarIntif the bytes are not a valid varint.
Whatever did arrive stays in the buffer in every case.
Sourcepub async fn read_control(
&mut self,
capture_raw: bool,
) -> Result<(AnyControlMessage, Option<Vec<u8>>), ConnectionError>
pub async fn read_control( &mut self, capture_raw: bool, ) -> Result<(AnyControlMessage, Option<Vec<u8>>), ConnectionError>
Read a control message from the stream.
When capture_raw is true, the returned tuple includes a clone of the
framed wire bytes (for observer emission). When false, the second
element is None and the payload clone is skipped.
Sourcepub async fn read_subgroup_header(
&mut self,
) -> Result<AnySubgroupHeader, ConnectionError>
pub async fn read_subgroup_header( &mut self, ) -> Result<AnySubgroupHeader, ConnectionError>
Read a subgroup stream header. Also initializes the internal delta-decoding state.
Sourcepub async fn read_fetch_header(
&mut self,
) -> Result<AnyFetchHeader, ConnectionError>
pub async fn read_fetch_header( &mut self, ) -> Result<AnyFetchHeader, ConnectionError>
Read a fetch response header.
Sourcepub async fn read_subgroup_object(
&mut self,
) -> Result<SubgroupObject, ConnectionError>
pub async fn read_subgroup_object( &mut self, ) -> Result<SubgroupObject, ConnectionError>
Read the next draft-18 subgroup object from this stream using
the stateful reader seeded by
FramedRecvStream::read_subgroup_header.
Errors with ConnectionError::PropertiesOnNonNormalStatus on an
Object that carries properties on a status other than Normal, which
draft-18 Section 11.2.1.2 answers with a session close. The Object is
consumed from the stream before the check, so the reader stays in step
with the wire and a caller that reports the violation and reads on sees
the following Object rather than a re-parse of this one.
Sourcepub async fn read_fetch_stream_header(
&mut self,
) -> Result<FetchHeader, ConnectionError>
pub async fn read_fetch_stream_header( &mut self, ) -> Result<FetchHeader, ConnectionError>
Read the next draft-18 fetch header from this stream.
Sourcepub fn stop(&mut self, code: u64) -> Result<(), ConnectionError>
pub fn stop(&mut self, code: u64) -> Result<(), ConnectionError>
Stop accepting data on this stream with code as the STOP_SENDING
application error code, discarding anything unread.
Dropping a receive stream also stops it, but with a hard-coded 0. See
RecvStream::stop.
Sourcepub async fn received_reset(&mut self) -> Result<Option<u64>, ConnectionError>
pub async fn received_reset(&mut self) -> Result<Option<u64>, ConnectionError>
Wait for the peer to reset this stream, consuming nothing.
See RecvStream::received_reset for what Ok(None) means and why a
caller must not re-poll after it.
Sourcepub fn begin_fetch_objects(&mut self, group_order: GroupOrder)
pub fn begin_fetch_objects(&mut self, group_order: GroupOrder)
Start reading the objects of a fetch stream whose Groups arrive in
group_order.
Section 11.4.4.1 makes a Group ID Delta count downward under Descending and upward under Ascending, so the same bytes are two different Locations and nothing on the data stream says which. The order is the one the request asked for — Section 10.12.3: “The publisher responding to a FETCH is responsible for delivering all available Objects in the requested range in the requested order” — carried by the GROUP_ORDER parameter on the FETCH, or by its absence, which Section 10.2.8 reads as Ascending. Either way it is a control message this stream never sees. Draft-19 encodes both IDs the same way and needs the same call; drafts 15, 16 and 17 resolve their fetch objects without an order, because none of those drafts encodes an ID as a difference.
Call it after FramedRecvStream::read_fetch_header and before the
first FramedRecvStream::read_fetch_object; calling it again restarts
the running state, which is what a second fetch stream on the same
connection would want and what the middle of one would not.
Sourcepub async fn read_fetch_object(
&mut self,
) -> Result<(FetchObject, Vec<u8>), ConnectionError>
pub async fn read_fetch_object( &mut self, ) -> Result<(FetchObject, Vec<u8>), ConnectionError>
Read the next draft-18 fetch object and its payload.
The mirror of FramedSendStream::write_fetch_object. What comes back
is a FetchObject rather than a header: draft-18’s reader resolves the
Location as it reads, and the resolved Group ID, Subgroup ID, Object ID
and Priority are the fields a subscriber acts on. The header it decoded
from is inside it.
The payload comes back with it because payload_length says how many
bytes follow, and a reader that takes the wrong number of them
desynchronises every later object on the stream.
§Errors
ConnectionError::DataStreamState when
FramedRecvStream::begin_fetch_objects has not been called,
ConnectionError::UnexpectedEnd when the stream ends inside the header
or inside the payload it declared, and ConnectionError::Codec on
every rule Section 11.4.4.1 states — a first Object that inherits, a
delta that runs off either end of the space, or an Object ID above
2^64-1.
Sourceasync fn read_object_payload(
&mut self,
length: &VarInt,
) -> Result<Vec<u8>, ConnectionError>
async fn read_object_payload( &mut self, length: &VarInt, ) -> Result<Vec<u8>, ConnectionError>
Take the length payload bytes that follow a fetch object’s header.
Separate from the header read because the header is decoded from a probe cursor that may have to be retried after a fill, and the payload is a flat byte count that never is.
Sourcepub fn draft(&self) -> DraftVersion
pub fn draft(&self) -> DraftVersion
Returns the draft version this stream is framed for.